Quote:
Originally Posted by Phil Nelson
So, what is the layman's answer to this question? If you fire up an unknown CRT on a tester, are you risking anything for a future rebuild? Or do you just go ahead on the theory that the damage (if any) has already been done?
Phil Nelson
|
If you fire up a gassy CRT at full heater voltage, it is very likely that the heater will quickly burn out. Since the heater and cathode are replaced during a rebuild, it is unlikely that a future rebuild would be adversely affected by doing so.
However, once the heater is burned out, a rebuild would be the ONLY option. No possibility of a rework (however slim) would exist. I guess that I would prefer to leave as many options open for as long as possible. Perhaps an attempt to seal the leaks followed by a getter re-flash and cathode re-activation could still rescue the tube, as long as the heaters remain intact. However, this is very unlikely and perhaps a waste of time and money, but at least the option remains open. If I had access to an RF generator and a getter "wand", I would try a getter re-flash in a New York Nanosecond... not much to loose!
jr