Quote:
Originally Posted by miniman82
Horizontal is still goofy. Something has GOT to be causing the HOT to draw excessive current, but I cannot figure out what it is. The loaded down horizontal section has got to be what's causing all the other issues, it's the only thing in common with every part of the set. Whatever it is, it doesn't seem to be affecting HV though.
|
Excessive horizontal output tube current can be due to a number of things. Is the horizontal drive correct? Excessive drive will cause excessive current.
What are the voltages around the tube? What does the horontal linearity look like? Depending how the linearity looks, that will provide a clue(s). How about a picture of a crosshatch pattern on the screen?
Have you checked and substituted the H O Tube? (Sorry, HOT to me means horizontal output transformer not tube). It could be gassy.
I am curious you say the EHT (+25,000v) is okay. How much curent is the 6BK4 shunt regulator drawing? It could be the EHT is low or high depending on the shunt current. Without the shunt, the EHT voltage should jump to +35000 to +40000. (Reminds me of the time my Grandma was watching her CTC11 and the shunt tube was bad. Her cat would like to sleep on the top of the set and she wondered why the cats hairs stood out. The EHT with my divider probe and VTVM measured +40000V. I suppose the cat had an especially good dose of Xrays when passing in front of the screen!
Terry