new HOT got the screen voltage in line, dropped from (128v tap)150 to 137 with just a tube change. The new tap seems to be fine, did not seem to drop the overall B+ much but I feel better about it anyway.
I noticed a slightly blue glow in the 3a3 so maybe its getting a bit gassy, will sub in one of those next. cathode current still a bit high about 205ma, was about 220ma before the tap and tube change.
|