If your Muntz has a solid state rectifier, especially if it has been upgraded from selenium, then the capacitors may temporarily exceed their voltage ratings during tube warm up. This will shorten their life.
Tube rectifiers like the 5U4 & 5Y3 intentionally have a controlled filament warm up to prevent this from happening.
|