I put the secondary in series with the primary, so the transformer will run a little cooler, and allows a higher input voltage without the transformer core saturating.
When putting it together, be prepared to reverse the secondary wire connections. Test the output to see if the voltage in fact is lower. If higher, reverse the secondary connections, but not the primary.