Posts: 15,413
Some field coil speakers had 'hum bucking coils' wound on the field coil....They would magnetically pick up the unwanted AC field in the field coil and feed it back to the voice coil 180 degrees out of phase thus cancelling any hum generated in the field coil.
__________________
Tom C.

Zenith: The quality stays in EVEN after the name falls off!