Quote:
Originally Posted by jr_tech
I would unsolder all of the connections to either pin 4 or pin 5 and mesure resistance between the two pins... leakage as high as 10 meg or so could mess up the bias on the tube.
You really need to get another HV probe, as low HV could be te main source of the problem.
jr
|
I thought maybe low hv but the crt is super bright and I tried adjusting the ring on the 1b3 and of course no change. Should the tube remain in the socket when I remove from one pin and test?