II know I am winding everyone up by posting this. But the set has I expect past 400 hours. In my pandemic office at home where I work, I have been runni g the set about six hours a day. CHCH-TV runs old sixties,/ seventies shows all day.
I had the set apart at about 350 hours to check the electrolytics. The two I tested (rectifier output) leakage was about 400uA at full rated voltage which is normal.
The only electrolytic which was bad was a tubular axial mount 25uF at the audio output supply. This,was replaced as it failed my original test. All others have remained original. And about half of the original paper capacitors I left if they were in the circuit shunted by a resistance of 100k ohm or lower. All the other paper capacitors have been changed.
A couple of resistors,were changed as they were out of tolerance and affected performance.
Here,are so.e snapshots from this afternoon oat via an RCA ATSC set top box.
Last edited by Penthode; 12-07-2020 at 10:43 PM.
|