As for the thermistor I got the same results from the new thermistor as the old one. None of this make any sense to me tracing the 145v to specific tubes and trace back to the power supply and there’s 175v. It still seems to me that something is crossed within the power supply cap network so I’m going to go back to this area and look again because it make no logical sense to have 175v at a 145v spot this voltage is coming from somewhere. Bottom line is I believe something is back feeding another circuit and I need to find it. I would think if something is pulling it down then all the voltages should be bottoming out but there not the circuit has no real amperage to keep voltage up during a short of some kind.

Last edited by timmy; 08-22-2022 at 07:44 AM.