Originally Posted by Alex KL-1 View Post
Outrageously busy now but... you can measure all, note that Schottky will have a typical low value of measurement (in the diode scale of a DMM), like 80-160 (after some seconds for charging the caps), you can need to remove only the ones that measure far from it (eg. if one measures 30, or short - near zero). Ordinary P-N diodes will measure 450-700.
Ok, i tested all the "similar in appearance" components mounted to 3 different heat sinks and got the following readings from each:
204 - YG862C15
689 - K3607
2.793 - YG971S8
847 - 06N903
1.180 - K8A50D
961 - K8A50D
1.676 - K20A60U
2.746 - Y0972S6

Not sure if I did this right but I had my meter set to diode testing. Triangle pointing to a line.