Quote:
Originally Posted by Chris K View Post
Thanks as always Kevin. Do you mind expanding on this a bit for me? I thought bias voltage just turned a tube on and off. There's a ramped relationship between bias on the grid and the plate output? Is a biasing voltage always a negative voltage? Since -4.8V is a higher voltage than -33 volts DC does that account for the higher current on the plate? Confused as usual by the details. Can you explain to me how a 6BG6 works other than the filament voltage?
You've pretty much got it. The negative bias on the grid(relative to cathode)sets the idle current, or operational point. So in some cases it can be turning on and off, like a switch, and other times it's partially on in neutral, so to speak. As far as I know normal receiving tubes use negative bias on the grid. If that's not clear I'll attempt to elaborate.