Quote:
|
Originally Posted by bobgary
Check capacitor C1001 .1uF (the cap between R1001 and R1002)
|
Since I had some .1s here I went ahead and changed that one. One of those ones crammed into that little shielded box underneath the #1 12ax7. Slight change in voltages, 61 is now 62, 130 is now 135, so still doesn't jibe with the schems of 165 and 100. I don't get it, if I measure that 175v across a 1 meg resistor, I get 88v, same as in the circuit, and when goes across the second 1 meg it drops it again to 62. How the heck is it supposed to be 165?? Is it possible that 165 is a typo and is supposed to be 65? Then again I still have 135 instead of 100 at the 12ax7 soooo - I dunno.