Steve,
Check out the TRK12/120/9/90 schematics in the Red Books. If you look at the power supply sections you'll see they have the main filter cap values (and a few other parts), in both the LV and HV sections, shown with a second value in parenthesis for 50cycle operation. For instance the HV caps are shown .03uF (.1uF 50 cycle) This is also the same on the TRK5/TT5 schematics. I have never seen a set that was actually setup this way, but perhaps this was for the LA market.

There is a section in the manual on the differences between the 50/60 sets. It mostly outlines the capacitor value changes, the transformer changes, the the LV rectifier changing to a 5T4. One very interesting aspect is these sets still ran on 60Hz video so the wobble in the picture when running them on 50Hz mains must have been a problem. They used a metal crt sleeve instead of the cardboard one and a double wall metal sleeve over the yoke. Still I imagine wobble would have been a problem.

Darryl
__________________
Converters for obsolete standards:
www.tech-retro.com/aurora-design/legacy.html

Last edited by tubesrule; 05-22-2015 at 09:02 AM.
Reply With Quote
 


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 04:04 AM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.