View Single Post
  #15  
Old 06-12-2024, 08:24 PM
Chris K Chris K is offline
VideoKarma Member
 
Join Date: Jun 2022
Posts: 1,505
Quote:
Originally Posted by Yamamaya42 View Post
40 volts too low on that rail, could be an issue, as it does power the sync separator and 2nd sync amp, and other areas.
I had the same sort of problems, but I really doubt it is the same as you are seeing now, but what ever it is, that voltage needs to come up to around where it should be.
I do have additional low voltages. The 275v is 263v. 135v is 101v. -2.0v is -1.7v. -18v is -18.8 and the -100v is -81. What the hell is going on? I'm supposed to have 350v DC on pin 8 of the 5V4 reaction scanning tube and it reads 330v. Supposed to have 300v going into the filter choke and I've got 285v.
Reply With Quote