Quote:
Originally Posted by Yamamaya42
40 volts too low on that rail, could be an issue, as it does power the sync separator and 2nd sync amp, and other areas.
I had the same sort of problems, but I really doubt it is the same as you are seeing now, but what ever it is, that voltage needs to come up to around where it should be.
|
I do have additional low voltages. The 275v is 263v. 135v is 101v. -2.0v is -1.7v. -18v is -18.8 and the -100v is -81. What the hell is going on? I'm supposed to have 350v DC on pin 8 of the 5V4 reaction scanning tube and it reads 330v. Supposed to have 300v going into the filter choke and I've got 285v.