C22 and 23 negatives connect at the same point at the end terminal on the "candohm" resister network.

I believe what seems confusing is that C23 should be tied to the pin 1 cathode of the 6X5. Then that wire goes to the field coil winding but it could be tied to that same point only, but at the other end of the wire. That's what you need to verify.

Also, C24 positive should be mounted to pin 4 of the 6F6 (which goes to the other side of the field coil), while the negative is at pin 8 of the 6F5.