Quote:
Go from the hold control coil (either terminal) all the way through the wave-shaping network of caps and resistors to pin 1 of the 6DQ5, which is not plugged in for this test. If 270 volts P-P is not found at the hold coil, the oscillator is not running. If something close is found, see where it gets stopped or attenuated.
__________________
"When resistors increase in value, they're worthless" -Dave G Last edited by DavGoodlin; 11-22-2016 at 03:19 PM. |