There is going to be some kind of short or excessive loading on the cathode end of the HV rectifier. Open the cage up and examine things carefully. Remove the rect socket from the cup and the insulator cup from the cage, clean and examine the cup for arc through damage (I've seen insulator cups fail) follow the wiring to the HV rect socket around and look for pinholes where it could have arced through. One of the more likely culprits is the HV rect filament winding. The filament winding typically consists of the same type of wire that the HV lead is made of wrapped loosely 1-3 turns around the frame of the flyback....Get some fresh (40KV rated) HV wire and replace it if it looks bad. What you were hearing is probably arcing/corona from the short. What you smelled was probably burning HV wire insulation or HV cup...Electrical arcing consists of a tiny path of superheated plasma...Arcing is hot enough to melt metal and easily hot enough to burn plastic which is probably what you are smelling. Do NOT allow your wife to throw it out! If the CRT is good that alone is a $100-300 part that is becoming scarse, the rest of the set also has value and I suspect if it were on my bench with the problems you describe I could have it working again in under an hour.