Old 02-07-2023, 10:18 PM
ThePlague ThePlague is offline
VideoKarma Member
 
Join Date: Apr 2017
Location: Denver, Colorado
Posts: 71
I went to check HOT collector to ground and sure enough there was continuity. There was also continuity between the HOT collector and emitter. I took the HOT out and rechecked the circuit without it. The collector side of the circuit was no longer grounded.

Long story short my HOT has failed and I was checking continuity for the collector (threads) incorrectly. There is a short from collector to emitter and collector to base. I will be sourcing a replacement.

I have also attached the requested pictures of my 22-5001 caps. They are in for troubleshooting rather than looks at the moment.

Update 1: From a quick glance, the Zenith replacements are all but gone. I was able to find sources for the RCA SK3115, Sylvania ECG165, and NTE165 replacements. Of course OEM is preferred, but is there any pecking order on other brand replacements?
Attached Images
File Type: jpg Image(13).jpg (77.8 KB, 27 views)
File Type: jpg Image(12).jpg (96.8 KB, 27 views)

Last edited by ThePlague; 02-07-2023 at 10:37 PM.
Reply With Quote
 



Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 07:46 AM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.